Tokyo National Research Institute for Cultural Properties Center for Conservation Science
Department of Art Research, Archives and Information Systems Japan Center for International Cooperation in Conservation
Department of Intangible Cultural Heritage


Air Quality Investigation in the Museum Display Cases

Injecting nitrogen into the bag set in the display case
Extracting the air from the bag using a pump

 The Center for Conservation Science investigates the conservation environments of museums. Recently, the Kanagawa Prefectural Museum of Cultural History requested us to investigate the air quality in their exhibition cases. They detected some organic acids, however, the emission source was not identified. The emission source was needed for taking appropriate counter-measures. Moreover, the ratio of acetic acid and formic acid is called for as the current measurement was taking them collectively as organic acids.

 Therefore, the Preventive Conservation and the Analytical Science Sections decided to investigate the emission source by applying the air quality investigation methods developed by the Analytical Science Section. Five points including the floors of two wall display cases (big and small size), the display surface of a tabletop case, the display stand, and the back panel, were targeted. As shown in the photos, the targeted measurement points were covered with bags made of airtight film and the 4.5 kg lead rings were set to seal them. Then, after replacing the air inside the bags with nitrogen and leaving them for 24 hours, the air was extracted from the bags using a pump, dissolved in ultrapure water, and analyzed using ion chromatography. Consequently, we measured the amount of acetic acid and formic acid emissions. Simultaneously, we checked the sealing degree by the measurement of CO2 density change inside bags over time.

 We have identified the density of acetic acid and formic acid at each measurement point and will leverage these outcomes for future air quality improvement.


to page top